Comparison of CO2- and SF6- based tracer gas methods for the estimation of ventilation rates in a naturally ventilated dairy barn. | |
Nadège E; Mosquera J; van Dooren HJC; Mendes LB; Ogink NWM | |
发表日期 | 2016 |
出处 | Biosystems Engineering 149: 11-23 |
出版年 | 2016 |
语种 | 英语 |
摘要 | Livestock production is a source of numerous environmental problems caused by pollutant gas emissions. In naturally ventilated buildings, estimating air flow rate is complicated due to changing climatic conditions and the difficulties in identifying inlets and outlets. To date no undisputed reference measurement method has been identified. The objective of this paper was to compare CO2- and SF6-based tracer gas methods for the estimation of ventilation rates (VRCO2 vs. VRSF6 ) in naturally ventilated dairy barns both under conventional and very open ventilation situations with different spatial sampling strategies. Measurements were carried out in a commercial dairy barn, equipped with an injection system for the controlled release of SF6, and measurement points for the monitoring of SF6 and CO2 concentrations to consider both horizontal and vertical variability. Methods were compared by analysing daily mean VRCO2=VRSF6 ratios. Using the average gas concentration over the barn length led to more accurate ventilation rates than using one single point in the middle of the barn. For conventional ventilation situations, measurements in the ridge seem to be more representative of the barn average than in the middle axis. For more open situations, both VRCO2 and VRSF6 were increased, VRCO2=VRSF6 ratios being also more variable. Generally, both methods for the estimation of ventilation rates gave similar results, being 10-12% lower with the CO2 mass balance method compared to SF6 based measurements. The difference might be attributed to potential bias in both methods. |
主题 | Ecosystems Services and Management (ESM) |
关键词 | Dairy barn, Natural ventilation, Air flow rate, CO2 mass balance, Tracer gas |
URL | http://pure.iiasa.ac.at/id/eprint/13308/ |
来源智库 | International Institute for Applied Systems Analysis (Austria) |
引用统计 | |
资源类型 | 智库出版物 |
条目标识符 | http://119.78.100.153/handle/2XGU8XDN/130539 |
推荐引用方式 GB/T 7714 | Nadège E,Mosquera J,van Dooren HJC,et al. Comparison of CO2- and SF6- based tracer gas methods for the estimation of ventilation rates in a naturally ventilated dairy barn.. 2016. |
条目包含的文件 | ||||||
文件名称/大小 | 资源类型 | 版本类型 | 开放类型 | 使用许可 | ||
Edouard%20et%20al%20(1668KB) | 智库出版物 | 限制开放 | CC BY-NC-SA | 浏览 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。